5.0 Menu Interface

The menu interface can be reached via two ways; serially via the DB25 connector or by Telnet via the
Ethernet Interface. This section will describe the different menus available on the radio.
Configurable settings are followed by information in brackets. The information includes a comma-
separated list of possible values then a semicolon and the default value. For example, a setting followed
by [
,
;
disabled
enabled
disabled
." In some cases, the parameter may be freeform for a customer to enter information. In that
is
disabled
case, the minimum and maximum of characters the parameter can take will be listed.
Login with the administrator user name and password. When logged in, the Starting Information Screen is
displayed.
Device Name – User-configured name for this radio. Set this from the Device Names menu.
IP Address – IP address for this radio. Set this from the IP Configuration menu.
Device Status – This is a display of the status of the radio and can be the following;
Location – User-configured location for this radio. Set this from the Device Names menu.
Serial Number – The manufacturer's serial number for this radio. Set by the factory and cannot
be changed.
Uptime – The elapsed time since the radio was started.
Current Firmware – The version number of the currently operating firmware.
Current User – The current user's login level.
16
] means the possible values are
Figure 10. Starting Information Screen
Initializing – appears during startup and/or internal RF deck
reprogramming.
Operational – when functioning properly.
Alarmed – when an error condition(s) exists. Click the letter "A" on the
keyboard to view the alarm.
TD220MAX Technical Manual
or
and the default value
disabled
enabled
MDS 05-6906A01, Rev R