DR3
Value
35
DR4
DIF (8 digit BCD Stor. 1)
36
DR4
VIF (Volume l)
37
DR4
Value LSB
38
DR4
Value
39
DR4
Value ( = 12345,678 m³)
40
DR4
Value MSB
41
DR5
DIF (Date Stor. 1;Type G)
42
DR5
VIF (Date + Extension)
43
DR5
VIFE (Future Value)
44
DR5
Value
45
DR5
Value
46
DR6
DIF (8 digit BCD)
47
DR6
VIF (Volume l + Extension)
48
DR6
VIFE (backward flow)
49
DR6
Value LSB
50
DR6
Value
51
DR6
Value ( = 0,003 m³)
52
DR6
Value MSB
53
DR7
DIF (Date Max. Value; Type G)
54
DR7
VIF (Date)
55
DR7
Value
56
DR7
Value
57
DR8
DIF (32 bit Int, Max. Value)
58
DR8
VIF (Flow Rate l/h)
59
DR8
Value
60
DR8
Value
61
DR8
Value
62
DR8
Value
63
DR9
DIF (32 Bit Int)
64
DR9
VIF (Flow Rate l/h)
65
DR9
Value
66
DR9
Value
67
DR9
Value
68
DR9
Value
69
DR10
DIF (Backflow Alarm Date; Type F)
70
DR10
DIFE (Storage No. 7)
71
DR10
VIF (Date, Time)
72
DR10
Value LSB
73
DR10
Value
74
DR10
Value
75
DR10
Value MSB
76
DR11
DIF (Manipulation Alarm Date; Type F)
77
DR11
DIFE (Storage No. 6)
78
DR11
VIF (Date, Time)
79
DR11
Value LSB
80
DR11
Value
81
DR11
Value
82
Falcon MJ M-Bus Operating instructions
05/18 Generation 1.2
xxh
4Ch
13h
78h
56h
34h
12h
42h
ECh
7Eh
xxh
xxh
0Ch
93h
3Ch
03h
00h
00h
00h
12h
6Ch
xxh
xxh
14h
3Bh
xxh
xxh
xxh
xxh
04h
3Bh
xxh
xxh
xxh
xxh
C4h
03h
6Dh
xxh
xxh
xxh
xxh
84h
03h
6Dh
xxh
xxh
xxh
Page 31 of 38