Long - Telegram (For Modules With Firmware 1.0.3 Or Older) - Honeywell FALCON MJ Pulse/M-Bus Operating Instructions Manual

M-bus module for honeywell / elster m100i and m120i waters meters
Table of Contents

Advertisement

DR12
80
DR12
81
Checksum
82
Stop
83
Long – telegram (for Modules with Firmware 1.0.3 or older)
4.2.2
Long telegram with monthly values.
Frame 1:
Field Name Content
Byte No
Start
1
L Field
2
L Field
3
Start
4
C Field
5
A-Field
6
CI Field
7
8 Ident.Nr.
9 Ident.Nr.
10 Ident.Nr.
11 Ident.Nr.
12 Manufr
13 Manufr
14 Version
15 Device type
16 Access No.
17 Status
18 Config Field
19 Config Field
DR1
20
DR1
21
DR1
22
DR1
23
DR1
24
DR1
25
DR2
26
DR2
27
DR2
28
Falcon MJ M-Bus Operating instructions
DIF (Manufacturerspecific)
PBIT
Stop byte
RSP-UD (M-Bus)
OMS M-Bus frame
Start byte
Length of data (xx bytes)
Length of data (xx bytes)
Start byte
Respond user data
Secondary addressing mode
72h (long header)
Ident No LSB (BCD)
Ident No (BCD)
Ident No (BCD) (=12345678)
Ident No MSB (BCD)
Manufacturer code
Manufacturer code
Version (or Generation number)
Device type (Medium=Water)
Access number of Meter
M-Bus state
no Encryption
no Encryption
DIF (8 digit BCD)
VIF (Volume l)
Value LSB
Value
Value ( = 28504,273 m³)
Value MSB
DIF (Time at readout; Type F)
VIF (Date, Time)
Value LSB
05/18 Generation 1.2
0Fh
xxh
xxh
16h
Meter
example
Bytes
[hex]
68h
xxh
xxh
68h
08h
FDh
72h
78h
56h
34h
12h
92h
15h
xxh
07h
2Ah
00h
00h
00h
0Ch
13h
73h
42h
50h
28h
04h
6Dh
32h
Page 19 of 38