Mounting the Sensor using AIR-AP-BRACKET-NS

The Cisco Aironet 1800s wireless sensor can be mounted, in a vertical orientation, on a wall or desk,
to a height of 3 feet, using the wall-mount bracket AIR-AP-BRACKET-NS.
To mount the sensor, follow these instructions:
Step 1
Identify the location for mounting the sensor.
Step 2
Use the wall-mount bracket AIR-AP-BRACKET-NS, as a template to mark the two screw-hole
locations for fastening the bracket to the wall or desk.
Step 3
At the marked locations, drill a hole into the wall or desk.
Step 4
Fasten the AIR-AP-BRACKET-NS to the wall using two 18mm screws.
Step 5
Hold the back of the sensor against the wall, above the bracket, and then slide the sensor
down onto the bracket, till it clicks into place. The hooks on the bracket will click into the
recesses on the back of the sensor.
Step 6
Proceed with connecting the data and power cables.
The sensor can be powered using:
• AC power, using the AC-USB adapter AIR-MOD-USB, supplying 5V DC, 1.5A power.
• PoE, 802.3af Class 0 power or greater, from:
a network device or power injector.
Cisco power injectors AIR-PWRINJ5 (for 802.3af) or AIR-PWRINJ6 (for 802.3at).
The PoE and USB ports are located on the base of the sensor. When both AC power and PoE power is
available, the PoE power takes precedence.