Sony DVS-9000SF User Manual page 208

With ccp-9000 series center control panel
Hide thumbs Also See for DVS-9000SF:
Table of Contents

Advertisement

3
4
5
208
Snapshot Operations From the Numeric Keypad Control Block
The first pressed button lights green as the reference region, and
subsequently pressed buttons light amber.
For details of the precedence order for becoming the reference region, see
"Regions and registers" in Chapter 1 (Volume 1).
The display shows the name of the reference region and the number of the
register previously recalled for that region.
Enter the desired register number from the numeric keypad.
See step 5 (page 206) in "Saving a snapshot from the numeric keypad
control block."
The entered register number appears in the display.
To apply temporary attributes, press the following buttons, turning them
on.
Control block
Temporary
attribute to apply
Cross-point control
A/B bus cross-point
block
hold
Key cross-point hold [XPT HOLD] button
Numeric keypad
Effect dissolve
control block
Auto transition
a) Enabled by a setup setting (page 285).
For the setup setting, see "Operation Settings (Operation Menu)" (page
282).
For details of temporary attributes and available attributes, see "Snapshot
Attributes" in Chapter 1 (Volume 1).
Notes
• The cross-point hold and key disable settings are maintained until you
next press the [XPT HOLD] button.
• Applying temporary attributes does not affect the contents of the
register.
• It is not possible to apply temporary attributes to a master snapshot.
Press the [ENTER] button.
This recalls the specified snapshot, and the reference region name and
recalled register number appear in the display.
Button
[XPT HOLD] button in the
background A/B bus
a)
[+/–/EFF DISS] button
[CLR/AUTO TRANS] button

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dvs-9000

Table of Contents