GE B30 Instruction Manual page 490

Ur series bus differential system protection relay
Hide thumbs Also See for B30:
Table of Contents

Advertisement

B.4 MEMORY MAPPING
Table B–10: MODBUS MEMORY MAP (Sheet 42 of 64)
ADDR
REGISTER NAME
A280
Selector 1 Function
A281
Selector 1 Range
A282
Selector 1 Timeout
A283
Selector 1 Step Up
B
A285
Selector 1 Step Mode
A286
Selector 1 Acknowledge
A288
Selector 1 Bit0
A28A
Selector 1 Bit1
A28C
Selector 1 Bit2
A28E
Selector 1 Bit Mode
A28F
Selector 1 Bit Acknowledge
A291
Selector 1 Power Up Mode
A292
Selector 1 Target
A293
Selector 1 Events
A294
Reserved (10 items)
A29E
...Repeated for Selector 2
Digital Counter (Read/Write Setting) (8 modules)
A300
Digital Counter 1 Function
A301
Digital Counter 1 Name
A307
Digital Counter 1 Units
A30A
Digital Counter 1 Block
A30C
Digital Counter 1 Up
A30E
Digital Counter 1 Down
A311
Digital Counter 1 Preset
A313
Digital Counter 1 Compare
A315
Digital Counter 1 Reset
A317
Digital Counter 1 Freeze/Reset
A319
Digital Counter 1 Freeze/Count
A31B
Digital Counter 1 Set To Preset
A31D
Reserved (11 items)
A328
...Repeated for Digital Counter 2
A350
...Repeated for Digital Counter 3
A378
...Repeated for Digital Counter 4
A3A0
...Repeated for Digital Counter 5
A3C8
...Repeated for Digital Counter 6
A3F0
...Repeated for Digital Counter 7
A418
...Repeated for Digital Counter 8
FlexCurves C and D (Read/Write Setting)
A600
FlexCurve C (120 items)
A680
FlexCurve D (120 items)
Non Volatile Latches (Read/Write Setting) (16 modules)
A700
Non-Volatile Latch 1 Function
A701
Non-Volatile Latch 1 Type
A702
Non-Volatile Latch 1 Set
A704
Non-Volatile Latch 1 Reset
A706
Non-Volatile Latch 1 Target
A707
Non-Volatile Latch 1 Events
B-50
RANGE
0 to 1
1 to 7
3 to 60
0 to 4294967295
0 to 1
0 to 4294967295
0 to 4294967295
0 to 4294967295
0 to 4294967295
0 to 1
0 to 4294967295
0 to 2
0 to 2
0 to 1
---
0 to 1
---
---
0 to 4294967295
0 to 4294967295
0 to 4294967295
–2147483647 to
2147483647
–2147483647 to
2147483647
0 to 4294967295
0 to 4294967295
0 to 4294967295
0 to 4294967295
---
0 to 65535
0 to 65535
0 to 1
0 to 1
0 to 4294967295
0 to 4294967295
0 to 2
0 to 1
B30 Bus Differential System
APPENDIX B
UNITS
STEP
FORMAT
---
1
F102
---
1
F001
s
0.1
F001
---
1
F300
---
1
F083
---
1
F300
---
1
F300
---
1
F300
---
1
F300
---
1
F083
---
1
F300
---
1
F084
---
1
F109
---
1
F102
---
1
F001
---
1
F102
---
---
F205
---
---
F206
---
1
F300
---
1
F300
---
1
F300
---
1
F004
---
1
F004
---
1
F300
---
1
F300
---
1
F300
---
1
F300
---
---
F001
ms
1
F011
ms
1
F011
---
1
F102
---
1
F519
---
1
F300
---
1
F300
---
1
F109
---
1
F102
DEFAULT
0 (Disabled)
7
50
0
0 (Time-out)
0
0
0
0
0 (Time-out)
0
0 (Restore)
0 (Self-reset)
0 (Disabled)
0
0 (Disabled)
"Counter 1"
(none)
0
0
0
0
0
0
0
0
0
0
0
0
0 (Disabled)
0 (Reset
Dominant)
0
0
0 (Self-reset)
0 (Disabled)
GE Multilin