APPENDIX B
Table B–10: MODBUS MEMORY MAP (Sheet 35 of 63)
ADDR
REGISTER NAME
723C
Neutral Directional Overcurrent 1 Polarizing Voltage
723D
Neutral Directional Overcurrent 1 Op Current
723E
Neutral Directional Overcurrent 1 Offset
723F
Neutral Directional Overcurrent 1 Pos Seq Restraint
7240
Reserved
7241
...Repeated for Neutral Directional Overcurrent 2
Breaker Arcing Current Settings (Read/Write Setting) (2 modules)
7290
Breaker 1 Arcing Amp Function
7291
Breaker 1 Arcing Amp Source
7292
Breaker 1 Arcing Amp Init
7294
Breaker 1 Arcing Amp Init B
7296
Breaker 1 Arcing Amp Init C
7298
Breaker 1 Arcing Amp Delay
7299
Breaker 1 Arcing Amp Limit
729A
Breaker 1 Arcing Amp Block
729C
Breaker 1 Arcing Amp Target
729D
Breaker 1 Arcing Amp Events
729E
...Repeated for Breaker 2 Arcing Amp
Disconnect (Breaker) Switch (Read/Write Setting) (8 modules)
74A0
Disconnect Switch 1 Function
74A1
Disconnect Switch 1 Name
74A4
Disconnect Switch 1 Mode
74A5
Disconnect Switch 1 Open
74A7
Disconnect Switch 1 Block Open
74A9
Disconnect Switch 1 Close
74AB
Disconnect Switch 1 Block Close
74AD
Disconnect Switch 1 Phase A / Three-pole Closed
74AF
Disconnect Switch 1 Phase A / Three-pole Opened
74B1
Disconnect Switch 1 Phase B Closed
74B3
Disconnect Switch 1 Phase B Opened
74B5
Disconnect Switch 1 Phase C Closed
74B7
Disconnect Switch 1 Phase C Opened
74B9
Disconnect Switch 1 Operate Time
74BA
Disconnect Switch 1 Alarm Delay
74BC
Disconnect Switch 1 Events
74BD
Reserved (2 items)
74BF
...Repeated for Disconnect Switch 2
74DE
...Repeated for Disconnect Switch 3
74FD
...Repeated for Disconnect Switch 4
751C
...Repeated for Disconnect Switch 5
753B
...Repeated for Disconnect Switch 6
755A
...Repeated for Disconnect Switch 7
7579
...Repeated for Disconnect Switch 8
Thermal Overload Protection (Read/Write Settings) (2 modules)
7788
Thermal Protection 1 Function
7789
Thermal Protection 1 Source
778A
Thermal Protection 1 Base Current
778B
Thermal Protection 1 K Factor
778C
Thermal Protection 1 Trip Time Constant
778D
Thermal Protection 1 Reset Time Constant
778E
Thermal Protection 1 Minimum Reset Time
778F
Thermal Protection 1 Reset
7791
Thermal Protection 1 Block
7793
Thermal Protection 1 Target
GE Multilin
RANGE
0 to 1
0 to 1
0 to 250
0 to 0.5
0 to 1
0 to 1
0 to 5
0 to 4294967295
0 to 4294967295
0 to 4294967295
0 to 65.535
0 to 50000
0 to 4294967295
0 to 2
0 to 1
0 to 1
---
0 to 1
0 to 4294967295
0 to 4294967295
0 to 4294967295
0 to 4294967295
0 to 4294967295
0 to 4294967295
0 to 4294967295
0 to 4294967295
0 to 4294967295
0 to 4294967295
0 to 65.535
0 to 65.535
0 to 1
---
0 to 1
0 to 5
0.2 to 3
1 to 1.2
0 to 1000
0 to 1000
0 to 1000
0 to 4294967295
0 to 4294967295
0 to 2
L30 Line Current Differential System
B.4 MEMORY MAPPING
UNITS
STEP
FORMAT
---
1
F231
0 (Calculated V0)
---
1
F196
0 (Calculated 3I0)
ohms
0.01
F001
---
0.001
F001
---
1
F001
---
1
F102
---
1
F167
---
1
F300
---
1
F300
---
1
F300
s
0.001
F001
kA2-cyc
1
F001
---
1
F300
---
1
F109
---
1
F102
---
1
F102
---
---
F206
---
1
F157
---
1
F300
---
1
F300
---
1
F300
---
1
F300
---
1
F300
---
1
F300
---
1
F300
---
1
F300
---
1
F300
---
1
F300
s
0.001
F001
s
0.001
F003
---
1
F102
---
---
F001
---
1
F102
---
1
F167
pu
0.01
F001
---
0.05
F001
min.
1
F001
min.
1
F001
min.
1
F001
---
1
F300
---
1
F300
---
1
F109
DEFAULT
0
63
0
B
0 (Disabled)
0 (SRC 1)
0
0
0
0
1000
0
0 (Self-reset)
0 (Disabled)
0 (Disabled)
"SW 1"
0 (3-Pole)
0
0
0
0
0
0
0
0
0
0
70
0
0 (Disabled)
0
0 (Disabled)
0 (SRC 1)
80
110
45
45
20
0
0
0 (Self-reset)
B-43

Advertisement

Table of Contents
loading