GE L30 Instruction Manual page 525

Line current differential system ur series
Hide thumbs Also See for L30:
Table of Contents

Advertisement

APPENDIX B
Table B–10: MODBUS MEMORY MAP (Sheet 7 of 63)
ADDR
REGISTER NAME
15A8
Direct Input 1-2 State (8 items)
15B0
Direct Input 1 State
15B1
Direct Input 2 State
Field Unit Input/Output States (Read Only)
15E0
Field Unit Contact Input States (3 items)
15E3
Field Unit Contact Input Output Operand States (8 items)
15EB
Field Contact Output Physical States (8 items)
15F3
Field Contact Output Current States (8 items)
15FB
Field Contact Output Physical States (8 items)
1603
Field Shared Input States
1604
Field Shared Input Channel States
1605
Field Shared Input Test States
1606
Field Shared Output Operand States
1607
Field Latching Output Open Operand States
1608
Field Latching Output Close Operand States
1609
Field Latching Output Open Driver States
160A
Field Latching Output Close Driver States
160B
Field Latching Output Physical States
160C
Field Unit Online/Offline States
160D
Field RTD Input Trouble States
160E
Field Transducer Input Trouble States
Ethernet Fibre Channel Status (Read Only)
1610
Ethernet Primary Fibre Channel Status
1611
Ethernet Secondary Fibre Channel Status
1612
Ethernet Tertiary Fibre Channel Status
Data Logger Actual Values (Read Only)
1618
Data Logger Channel Count
1619
Time of Oldest Available Samples
161B
Time of Newest Available Samples
161D
Data Logger Duration
87L Channel Status Actual Values (Read Only)
1638
Channel 1 Asymmetry
163A
Channel 2 Asymmetry
Field Unit RTD Actuals (Read Only) (8 modules)
16C0
Field RTD 1 Value
16C1
...Repeated for Field RTD 2
16C2
...Repeated for Field RTD 3
16C3
...Repeated for Field RTD 4
16C4
...Repeated for Field RTD 5
16C5
...Repeated for Field RTD 6
16C6
...Repeated for Field RTD 7
16C7
...Repeated for Field RTD 8
Field Unit Transducer Actuals (Read Only) (8 modules)
16C8
Field Transducer 1 Value
16CA
...Repeated for Field Transducer 2
16CC
...Repeated for Field Transducer 3
16CE
...Repeated for Field Transducer 4
16D0
...Repeated for Field Transducer 5
16D2
...Repeated for Field Transducer 6
16D4
...Repeated for Field Transducer 7
16D6
...Repeated for Field Transducer 8
Source Current (Read Only) (2 modules)
1800
Source 1 Phase A Current RMS
1802
Source 1 Phase B Current RMS
GE Multilin
RANGE
0 to 1
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 2
0 to 2
0 to 2
0 to 16
0 to 4294967295
0 to 4294967295
0 to 999.9
-65.535 to 65.535
-99.999 to 99.999
-32768 to 32767
-32.768 to 32.767
0 to 999999.999
0 to 999999.999
L30 Line Current Differential System
B.4 MEMORY MAPPING
UNITS
STEP
FORMAT
---
1
F108
---
1
F500
---
1
F500
---
1
F500
---
1
F500
---
1
F500
---
1
F500
---
1
F500
---
1
F500
---
1
F500
---
1
F500
---
1
F500
---
1
F500
---
1
F500
---
1
F500
---
1
F500
---
1
F500
---
1
F500
---
1
F500
---
1
F500
---
1
F134
---
1
F134
---
1
F134
channel
1
F001
seconds
1
F050
seconds
1
F050
days
0.1
F001
ms
0.001
F004
ms
0.001
F004
°C
1
F002
---
0.001
F004
A
0.001
F060
A
0.001
F060
DEFAULT
0 (Off)
0
0
0
B
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0 (Fail)
0 (Fail)
0 (Fail)
0
0
0
0
0
0
0
0
0
0
B-15

Advertisement

Table of Contents
loading

Table of Contents