B.4 MEMORY MAPPING
Table B–10: MODBUS MEMORY MAP (Sheet 34 of 63)
ADDR
REGISTER NAME
6447
Negative Sequence Overvoltage 1 Target
6448
Negative Sequence Overvoltage 1 Events
6449
...Repeated for Negative Sequence Overvoltage 2
6452
...Repeated for Negative Sequence Overvoltage 3
Phase Undervoltage (Read/Write Grouped Setting) (3 modules)
B
7000
Phase Undervoltage 1 Function
7001
Phase Undervoltage 1 Signal Source
7002
Phase Undervoltage 1 Pickup
7003
Phase Undervoltage 1 Curve
7004
Phase Undervoltage 1 Delay
7005
Phase Undervoltage 1 Minimum Voltage
7006
Phase Undervoltage 1 Block
7008
Phase Undervoltage 1 Target
7009
Phase Undervoltage 1 Events
700A
Phase Undervoltage 1 Measurement Mode
700B
Reserved (6 items)
7011
...Repeated for Phase Undervoltage 2
7022
...Repeated for Phase Undervoltage 3
Phase Overvoltage (Read/Write Grouped Setting) (3 modules)
7040
Phase Overvoltage 1 Function
7041
Phase Overvoltage 1 Source
7042
Phase Overvoltage 1 Pickup
7043
Phase Overvoltage 1 Delay
7044
Phase Overvoltage 1 Reset Delay
7045
Phase Overvoltage 1 Block
7047
Phase Overvoltage 1 Target
7048
Phase Overvoltage 1 Events
7049
...Repeated for Phase Overvoltage 2
7052
...Repeated for Phase Overvoltage 3
Phase Directional Overcurrent (Read/Write Grouped Setting) (2 modules)
7200
Phase Directional Overcurrent 1 Function
7201
Phase Directional Overcurrent 1 Source
7202
Phase Directional Overcurrent 1 Block
7204
Phase Directional Overcurrent 1 ECA
7205
Phase Directional Overcurrent 1 Pol V Threshold
7206
Phase Directional Overcurrent 1 Block Overcurrent
7207
Phase Directional Overcurrent 1 Target
7208
Phase Directional Overcurrent 1 Events
7209
Reserved (8 items)
7211
...Repeated for Phase Directional Overcurrent 2
Neutral Directional Overcurrent (Read/Write Grouped Setting) (2 modules)
7230
Neutral Directional Overcurrent 1 Function
7231
Neutral Directional Overcurrent 1 Source
7232
Neutral Directional Overcurrent 1 Polarizing
7233
Neutral Directional Overcurrent 1 Forward ECA
7234
Neutral Directional Overcurrent 1 Forward Limit Angle
7235
Neutral Directional Overcurrent 1 Forward Pickup
7236
Neutral Directional Overcurrent 1 Reverse Limit Angle
7237
Neutral Directional Overcurrent 1 Reverse Pickup
7238
Neutral Directional Overcurrent 1 Target
7239
Neutral Directional Overcurrent 1 Block
723B
Neutral Directional Overcurrent 1 Events
B-42
RANGE
0 to 2
0 to 1
0 to 1
0 to 5
0 to 3
0 to 1
0 to 600
0 to 3
0 to 4294967295
0 to 2
0 to 1
0 to 1
0 to 1
0 to 1
0 to 5
0 to 3
0 to 600
0 to 600
0 to 4294967295
0 to 2
0 to 1
0 to 1
0 to 5
0 to 4294967295
0 to 359
0 to 3
0 to 1
0 to 2
0 to 1
0 to 1
0 to 1
0 to 5
0 to 4
-90 to 90
40 to 90
0.006 to 30
40 to 90
0.006 to 30
0 to 2
0 to 4294967295
0 to 1
L30 Line Current Differential System
APPENDIX B
UNITS
STEP
FORMAT
---
1
F109
---
1
F102
---
1
F102
---
1
F167
pu
0.001
F001
---
1
F111
0 (Definite Time)
s
0.01
F001
pu
0.001
F001
---
1
F300
---
1
F109
---
1
F102
---
1
F186
---
1
F001
---
1
F102
---
1
F167
pu
0.001
F001
s
0.01
F001
s
0.01
F001
---
1
F300
---
1
F109
---
1
F102
---
1
F102
---
1
F167
---
1
F300
---
1
F001
pu
0.001
F001
---
1
F126
---
1
F109
---
1
F102
---
1
F001
---
1
F102
---
1
F167
---
1
F230
° Lag
1
F002
degrees
1
F001
pu
0.001
F001
degrees
1
F001
pu
0.001
F001
---
1
F109
---
1
F300
---
1
F102
DEFAULT
0 (Self-reset)
0 (Disabled)
0 (Disabled)
0 (SRC 1)
1000
100
100
0
0 (Self-reset)
0 (Disabled)
0 (Phase to
Ground)
0
0 (Disabled)
0 (SRC 1)
1000
100
100
0
0 (Self-reset)
0 (Disabled)
0 (Disabled)
0 (SRC 1)
0
30
700
0 (No)
0 (Self-reset)
0 (Disabled)
0
0 (Disabled)
0 (SRC 1)
0 (Voltage)
75
90
50
90
50
0 (Self-reset)
0
0 (Disabled)