Cleaning

For light cleaning, use a soft, damp cloth to wipe down
the Compact2. If desired, you can use a disinfectant.
Using solvents to clean any part of the
NOTICE
system can affect waterproofing.
To thoroughly clean the Compact2, follow these steps:
1. Prepare:
• Disconnect the system cable from the digital re-
porting monitor and remove the monitor from the
docking system.
• Make sure the slip-ring dial is in the locked
position.
• Push the camera through all three push cable
guides and into the drum so the drum can spin
freely.
2. Stand the Compact2 upright and pour lukewarm
water and a mild detergent into the drum.
High pressure water can damage the
NOTICE
seals that protect the electronics inside
the drum.
Find Quality Products Online at:
GlobalTestSupply
www.
3. Spin the drum to loosen the debris.
4. Tip the drum opening down to empty the water.
5. In a large area, pull the push cable through the
guides and completely out of the drum. Do not try to
coil the push cable outside of the drum.
6. Use a hose to clean the empty drum.
7. Fully dry the Compact2. Run a rag over the push
cable while you push it back into the drum.