Troubleshooting - RIDGID seesnake compact2 Operator's Manual

Table of Contents

Advertisement

Problem
No video feedback
No count measurement
Find Quality Products Online at:

Troubleshooting

Probable Fault
No power to the SeeSnake
monitor.
Slip-ring assembly is broken
or the connection is faulty.
SeeSnake system cable
connection is faulty.
Camera is faulty.
Older SeeSnake monitors
may not be compatible with
the Compact2's integrated
counter.
GlobalTestSupply
www.
Solution
Check to make sure the power source is properly
connected.
Check all alignment and connection pins.
Check placement and pin condition in the slip-ring
assembly.
Check SeeSnake system cable connection. Make
sure the connectors are pushed all the way in.
Isolate the fault to the camera. Refer to Appendix B
for instructions.
Count measurements will show up on job reports,
and may show up on the monitor during viewing.
A new monitor may be required if capturing count
measurements to media is necessary.