Connect the DC Adapter for the 5506H-X
The black lead is negative or ground and the white lead is positive. The output cable is 1.3 meters and the input cable is
1 meter in length.
Figure 31: DC Power Adapter
Black wire (negative)
1
3
Adapter
Step 2
Plug the adapter cord into the ASA.
The power adapters have 18 AWG wires for the input connection. Tinned bare wires are used for the input
Note
connection because there is no standard established for connector type. Screw terminal blocks are most often
used.
Step 3
Power on the ASA and check that it has power. See
Cisco ASA 5506-X, ASA 5506W-X, and ASA 5506H-X Hardware Installation Guide
46
White wire (positive)
2
LEDs, on page 8
for information on the power LED.