Field for setting the parameters for TeleService access (IP address of the server)
Access data of the TeleService server (switching station).
In STEP 7, the corresponding data is located in the parameter area "TeleService settings".
If there is more than one TeleService server, use the field once per server.
Table 5- 21
IF_CONF_TS_IF_V4
Parameter
Id
Length
Mode
RemoteAddress
RemotePort
Rank
CP 1242-7
Operating Instructions, 09/2011, C79000-G8976-C247-02
Data type
Initial value
UINT
21
UINT
UINT
IP_V4
UINT
UINT
5.4 Configuring the telecontrol instructions
Description
ID of the parameter field
Length of the parameter field in bytes: 14
Validity (1: permanent, 2: temporary)
IP address of the TeleService server
Port of the TeleService server
Priority of the server [1] or [2]
1 = server 1, 2 = server 2
Configuration
73