How To Change Water Pump; Water Tank; Water Pump Wiring Connection - Honeywell CL30XC Service Manual

Evaporative air cooler
Hide thumbs Also See for CL30XC:
Table of Contents

Advertisement

2.2 How To Change Water Pump

Remove the rear panel follow the procedure 2.1.1.
2.2.1

Water Tank

Detach the water tank and use
screw driver to remove 10
galvanized screw with plate
head (ST3.5*10) on the bottom
plate.
Remove the water pump box
and remove the water tube.
2.2.2

Water Pump Wiring Connection

Remove the below 2 wiring cap
and use screw driver to remove
the ground connection screw
part.
Website:
Use screw driver to
remove 3 galvanized
screw with plate head
(ST3.5*10)
on
the
water pump box.
Use screw driver to
remove 2 galvanized
screw with plate head
(ST3.5*10)
of
the
wiring pressing piece
C.
11
CONFIDENTIAL
http://www.honeywellaircoolers.com
Use screw driver to
remove 2 galvanized
screw with plate head
(ST3.5*10)
of
the
wiring pressing piece
B.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Chl30xc

Table of Contents