5. Once the basic configuration of the
apparatus is entered, make sure that
"Model Is Active" box is selected and click
"Next".
6. At the First Stage Selection screen Double
Click on the appropriate first stage
connection from the left column. The
selection should then appear in the right
column.
In this example, we're configuring the first
stage for a 4500 PSI SCBA, so only first
stages that can be used with 4500 PSI are
shown:
4500 PSI, No MP Connection
4500 PSI, MP Connection, No Max Rate
4500 PSI, MP Connection, Max Rate
Note: MP Connection stands for Medium
Pressure. For SCBA that are entered into
the software with a Medium Pressure
connection in the Standard software, the
medium pressure readings will be shown
on tests where it is appropriate. The
Standard Software does not contain
tolerances for the medium pressure tests,
so there will be no indication whether the
medium pressure portion of the tests
passes or fails.
All brand-specific versions of Posi3 USB
Software include Medium Pressure tests
where appropriate (as defined by the
manufacturer). The inclusion of the Medium
Pressure connection allows the user to test
the output of the first stage according to the
manufacturer's specifications.
7. Once the selection is shown in the right
column, click "Next".
8. At the Regulator selection screen, double
click on the appropriate regulator from the
Available column so that it appears in the
column at right.
9. Once the selection is shown in the right
column, click "Next".
10. Double click on the Facepiece from the
Available column so that it appears in the
column at right. Then click "Next".
11. At the Alarms Selection screen, double
click on the appropriate Alarms from the
Available column so that the alarm
22