ID
FD04
FAIL
[Meaning] The temperature of CPU at the part shown in Y is beyond the warning level. X
shows "Upper" or "Lower".
[Action] The module with high temperature may stop working to protect hardware.
Consult your reseller or maintenance personnel.
Check if something prevents it from cooling down, such as failure in air conditioners or in
fan modules of the unit, and inlet ports covered with dust.
FD05
Info
[Meaning] The temperature of CPU at the part shown in Y is back to the normal level. X
shows "Upper" or "Lower".
[Action] No particular action required.
FD10
WARNING
[Meaning] The voltage at the part shown in Y is beyond the warning level. X shows
"Upper" or "Lower".
[Action] Although the device can keep running, the voltage level can cause a fault (the
message ID: FD11). Consult your reseller or maintenance personnel.
FD11
FAIL
[Meaning] The voltage at the part shown in Y is exceedingly high. X shows "Upper" or
"Lower".
[Action] The module with high voltage may stop working to protect hardware. Consult
your reseller or maintenance personnel.
FD12
Info
[Meaning] The voltage at the part shown in Y is back to the normal level. X shows
"Upper" or "Lower".
[Action] No particular action required.
FD30
Info
[Meaning] A module at the part shown in X is inserted.
[Action] Nothing is required.
FD31
Info
[Meaning] A module shown at the part in X is removed.
[Action] Nothing is required.
FD38
FAIL
[Meaning] Watchdog timeout at the part shown in X is detected.
[Action] Consult your reseller or maintenance personnel.
FD40
WARNING
Hitachi Compute Blade 500 Series Management Module Setup Guide
Level
Description
Temperature of CPU became error level.
(Temp(X),Location:Y)
Temperature of CPU has been restored
to a normal level.(Temp(X),Location:Y)
Voltage became warning level.
(Voltage(X),Location:Y)
Voltage became error level.
(Voltage(X),Location:Y)
Voltage has been restored to a normal
level.(Voltage(X),Location:Y)
Module is installed.(Location:X)
Module is removed.(Location:X)
Watchdog timer has expired.(Location:X)
On server, an warning event occurred.
(Location:X,Event:Y)
HCSM alert log message