Troubleshooting

Troubleshooting the Cisco SCE 2000 Operational Status

Table 5 lists the operational states of the Cisco SCE 2000. The Status LED on the service control module reflects current
Cisco SCE 2000 operational status. To show operational status, enter the command show system operation-status. Table 6 lists
the LED status explanations.
Table 5
Cisco SCE 2000 Operational States
Cisco SCE 2000
Operational Status
Booting
Operational
Warning
Failure
Table 6
Power Supply LEDs
LED Label
IN
Description
Initial state after reset
Cisco SCE 2000 becomes operational after completing the following:
• Boot is completed
• Power self-tests are completed without failure
• Platform configuration is applied
Cisco SCE 2000 is fully operational (as above) but one of the following
occurred:
• Line ports (GBE ports) to the link are down
• Management port link is down
• Temperature raised above threshold
• Voltage not in required range
• Fans problem
• Power supply issue
• Insufficient space on the disk
Note
If the condition that caused the Cisco SCE 2000 to be in Warning
state is resolved (for example, link is up) the Cisco SCE 2000 reverts
to Operational state.
After bootup, system is in Failure state due to one of the following
conditions:
• Power-on test failure
• Three abnormal reboots in less than 20 minutes
• Platform configured to enter Failure mode consequent to
failure-induced reboot (this is configurable using CLI command)
• Severe system health problem, such as extensive overheating or voltage
out of correct operating range
Depending on the cause of failure, the management interface and the
Note
platform configuration may or may not be active or available.
Color
State
Function
Green
On
The input voltage is in the required range.
Off
The input voltage is not in the required range.
Status LED State
Amber
Steady green
Flashing amber
Red
25