QUESTION 09
MISCELLANEOUS SYSTEM OPTIONS
There are 4 locations (L1-L4) for system timing and system options, as follows:
Question 09 L1
Entry Delay 2
Using the table in Question 8, Location 1 to determine valid choices, enter the desired entry delay time
for zones 4-8. If zones 4-8 are delay zones, then they follow entry delay 2. For UL applications,
the maximum entry delay shall not exceed 45 seconds.
Question 09, L2
Remote Communications Ring Count
Selecting from the choices below, enter a digit in Location L2.
REMOTE COMMUNICATIONS
Digit
RING COUNT
0
NONE (Remote Communications Disabled)
1
1 RING
2
2 RINGS
3
3 RINGS
4
4 RINGS
5
5 RINGS
6
6 RINGS
7
7 RINGS
REMOTE COMMUNICATIONS RING COUNT - is the number of rings required for the control
panel to pick up and begin a remote communications session. Select a value that does not interfere with
normal operation of the panel. The default value is 12 rings.
NOTE: A value of 0 means that remote connect is disabled.
Question 09, L3
CS Test Time Interval
Digit
24 HOURS
0
1
2
3
4
5
9
A
B
C
D
CS TEST TIME INTERVAL
WEEKLY
27 DAYS
NONE (CS TEST DISABLED)
Section 7 - System Programming
REMOTE COMMUNICATIONS
Digit
8
8 RINGS
9
9 RINGS
A
10 RINGS
B
11 RINGS
C
12 RINGS
D
13 RINGS
E
14 RINGS
F
15 RINGS
60 DAYS
90 DAYS
DEFAULT = 2C06
Default = 2
Default = C
RING COUNT
Default = 0
CS TEST RESET BY
TIME
EVENT
7–11