Quick Bypass; Exit Bypass; Auto Unbypass; Manual Unbypass - Honeywell OMNI 408 Installation And Setup Manual

Fbii hardwired/wireless system
Table of Contents

Advertisement

OMNI-408/OMNI-408EU Installation and Setup Guide

Quick Bypass

Quick Bypass is a programmable option (see Question 07, Location 3 of the programming sequence)
that allows the user to bypass zones without using a user code.
Press the [BYPASS] key, followed by a number from 1 to 8 which represents the zone to be bypassed.
Example: To bypass zone 2, enter:
[BYPASS] [2]

Exit Bypass

Exit Bypass is a programmable option (see Question 26, Location 4 of the programming sequence). If
set, any delay zone or interior that is violated at the end of exit time will be bypassed for that armed
period. This feature, if selected, takes precedence over exit error.

Auto Unbypass

All burglary zones that are bypassed can be automatically unbypassed upon system disarm. 24-hour
zones that have been bypassed are unbypassed only if they are normal. This feature is ALWAYS
enabled.

Manual Unbypass

This function removes an existing bypass from a currently bypassed zone only while the system is
disarmed. The procedure is the same as Bypass.

User Code Programming

User codes can be entered or modified directly through the keypad. The system contains up to six user
codes (4 digits each) with the following applications:
NOTES:
1. User Number 1 - programs all user codes (1-6); cannot be deleted.
2. User Number 5 - can be programmed as an arm-only user in Question 07, Location 4. This means
that the user code can only arm, but not disarm, the system. Typically, this is used for a maid
service or any person with limited access.
3. User Number 6 - can be programmed as an Ambush code if there is an Ambush CS transmission
code programmed into Question 19, Locations 1 and 2. In this mode, entry of the user number 6
code will arm or disarm the system and transmit the Ambush code to the central station.
4–8
USER
APPLICATION
NUMBER
1
Master User (see note 1)
2
Normal User
3
Normal User
4
Normal User
5
Arm Only (see note 2)
6
Ambush (see note 3)
DEFAULT
CODE
1234
NULL
NULL
NULL
NULL
NULL

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Omni 408eu

Table of Contents