Grounding the Power Injector

We recommend that you ground the power injector after installing it. To ground the power injector,
follow these steps:
Attach the wire to a UL listed ring lug, suitable for conductor size. Be sure to double crimp the
Step 1
connection.Attach the ring lug to a mounting tab on the power injector.
Note
Attach other end of the wire to a permanent ground connection in the building installation.
Step 2

Installing the Power Injector

To install the power injector, follow these steps:
Plug a shielded outdoor rated Ethernet cable into the TO AP port on the power injector.
Step 1
Warning
Note
Plug the other end of the Ethernet cable into the Ethernet Port on the access point.
Step 2
Note
Plug a shielded outdoor rated Ethernet cable into the TO SWITCH port on the power injector.
Step 3
Warning
Plug the other end of the Ethernet cable into your Ethernet switch, hub, or network.
Step 4
Use a screw driver to tighten the screw into the wall anchor.
Use a minimum 12 AWG or 2.5 mm cross-sectional area, 90
for permanent ground connection.
To reduce the risk of fire, use only No. 26 AWG or larger telecommunication line cord.
Statement 1023
To comply with FCC regulations, the length of Ethernet cable connecting the power injector to
the access point cannot be less than 10 ft (3 m).
For detailed information about connecting the Ethernet cable to an access point, see the
Hardware Installation Guide for that access point.
To reduce the risk of fire, use only No. 26 AWG or larger telecommunication line cord.
Statement 1023
Cisco Aironet Series Power Injector AIR-PWRINJ1500-2= Installation Instructions
Grounding the Power Injector