Honeywell CDMA-X Installation And Setup Manual page 13

Intellipath series cdma communicator
Table of Contents

Advertisement

PROMPTS
13
Primary CS ID
(??)
14
Primary Sub ID
(????)
15
En. 2nd CS Y/N (N)
16
Device Address
(03)_
Remote Access enables the user to control the security system using a web browser. This feature must be configured at the AlarmNet Direct
website as follows:
• Remote Access must be enabled by selecting "Enabled" at the Remote Access prompt.
• A keypad address must be enabled in the communicator in order for it to communicate with the control panel.
• At the "Keypad Type" prompt, select the appropriate Keypad.
17
Remote Access Y/N
(N)_
18
Keypad Address
(28)_
19
Supervision
(24 Hours)_
20
Old Alarm Time
(10 Minutes)_
21
Cell Flt Time
(00 mins)_
CDMA-X Installation and Setup Guide
ENTRY
OPTIONS
[01-FE]
[0001-9999]
[Y], [N]
[01-30]
Setting up the Remote Access Feature
[Y], [N]
[01-30]
• 24 Hour
• None
• 30 Day
• 10 Minutes
• 15 Minutes
• 30 Minutes
• 1 Hour
• 2 Hours
• 4 Hours
• 8 Hours
• 12 Hours
• 24 Hours
[00-99]
[00] = not
used
– 11 –
DESCRIPTION
Enter the 2-digit primary central station ID number,
01-FE (HEX).
Enter the 4-digit subscriber account number, 0001-
9999 (decimal).
Applicable only if the control panel supports Central
Station #1 and #2 Category Enable reporting for the
communicator (or LRR) device (e.g., VISTA-128BP,
FA1660C, etc.).
Used if reporting to a second central station is desired.
The CDMA-X communicates with the control panel as
a communicator (or LRR) device. Enter the ECP
device address.
NOTE: When programming the control panel, enable
the communicator's (or LRR) output.
Press [Y] to allow the end user to access their system
via a website. Availability of this service is controlled
by the dealer via the web-based programming tool on
the AlarmNet Direct website.
NOTE: This prompt will only appear if the Remote
Access feature has been enabled.
Must be programmed if using the Remote Access
feature. Enter the appropriate device address.
The AlarmNet network must hear at least one
supervisory message from the communicator during
this supervision period; otherwise, AlarmNet notifies
the central station that a communication failure has
occurred. (If the supervision period is changed after
registration, you must re-register the communicator.)
Press the [space] key to scroll through choices.
NOTE: Must be 24 hour for compliance agency.
The old alarm time sets how long an undeliverable
alarm is retried for delivery to the central station. If
the message is not validated, it is retried until the old
alarm time is reached or the message is validated.
Press the [space] key to scroll through choices.
NOTE: Must be 10 minutes for compliance agency.
In the event the communicator detects a
communication path failure, enter the time delay (in
minutes) before the communicator notifies the control
panel with a trouble message. The control panel can
then notify the central station.
NOTE: Must be one (01) minute for compliance
agency.