PROMPTS
6
Enter Password
7
Verify Password
8
Exit Prog. Mode?
(Y/N)_
9
Device Mode
(ECP)_
NOTE: E-mail notification is intended as a convenience for the user, and does not replace Central Station reporting of critical events
(alarms, troubles, etc.).
Users can receive e-mail notification of system events by using the Multi-Mode feature. The following items must be met to use this feature.
In order for the Multi Mode, Remote Access, and Keypad Address programming fields to appear an account must be created in the
AlarmNet Direct website and "Remote Access" must be enabled for the comm device.
The communicator will emulate one or two 4204 relay modules to accommodate system events that are programmed in the control panel.
When programming the communicator, at prompt #10, choose 4204-Sourced so the user can be notified of up to four events, or choose
2-4204-Sourced so the user can be notified of up to eight system events.
The 4204 relay events used to trigger email notifications are defined on the Honeywell Total Connect website, and must correspond to
outputs (relays) programmed in the control panel through Output Device programming.
The Multi-Mode address selected at prompt #11 in the communicator (or at the AlarmNet Direct website) must match the address of a
4204 relay module enabled in the control panel (although you don't actually connect a module).
If using "2-4204-sourced," the address of the second module is automatically assigned the next device address after the first 4204. Make
sure that address is also enabled in the control panel.
10
Multi Mode
(Disabled)_
11
Multi Mode Addr (12)
NOTE: Account information is provided by the central station administrator.
12
Primary City ID (??)_
CDMA-X Installation and Setup Guide
ENTRY
OPTIONS
[0-9, A-F, N, S, T,
X, Y]
[0-9, A-F, N, S, T,
X, Y]
[Y], [N]
[ESC]
• ECP
• 4204 Emu
• Two 4204s
Setting up E-mail Notifications (Multi-Mode feature)
• Disabled
• 4204 Sourced
• 2-4204 Sourced
• Enhanced Reports
[01-30]
[01-99]
– 10 –
DESCRIPTION
This prompt is displayed if [Y] was pressed in Prompt
4 or 5.
Enter a 4-digit password
(0-9, A-F, N, S, T, X, Y).
Re-enter the password as confirmation.
If the password doesn't match the first entry, the
following is displayed followed by the "Exit Prog.
Mode?" prompt:
Verify Not OK
PSWD not created
Otherwise, the "Exit Prog. Mode?" prompt is displayed
directly.
Exits program mode.
Press [N] to go back to Prompt 3.
Press [ESC] to load factory defaults.
Refer to the Exiting the Programming Mode topic.
Press the [space] key to scroll through the modes of
operation.
Press [ENTER] to select the desired mode.
Enable if you want system events sent by e-mail to the
user. Select "4204 Sourced" to send up to four events,
or "2-4204 Sourced" to send up to eight events.
Disable for normal alarm processing and go to Prompt
12 "Primary City ID" prompt.
Select "Enhanced Reports" to enable reporting to TC2
web services. Note, to use "Enhanced Reports" ensure
the control panel is Total Connect 2.0 Ready.
This address must be programmed if using the Multi-
Mode (e-mail notification) feature. The device address
must be unique from the normal communicator (or
LRR) device address and the Keypad Address used for
Remote Access or Direct Wire downloading.
The address used must also be enabled as a 4204 relay
module in Vista and First Alert control panels.
Enter the 2-digit primary city ID,
01-99 (decimal).