R
epair
[5] DISASSEMBLY/ASSEMBLY
[5] -5. Motor Section, Torque Limiter Section
DISASSEMBLING
4) Disconnect connectors to disassemble Handle section as illustrated in Fig. 21.
Fig. 21
Disconnect the connector of Lead unit from Controller.
Handle section can be separated completely from machine.
In case of HR3541FC, disconnect the connector
of LED Circuit.
Controller and Cord clamp base can be
removed from Motor housing by unscrewing
4x18 Tapping screws.
5) Disconnect the contact between Carbon brush and Commutator as illustrated in Fig. 22.
Fig. 22
Disconnection of Carbon brush with Commutator
Detach Spiral spring
from Carbon brush.
By pulling Carbon brush,
disconnect the contact with
Armature's commutator.
Armature is ready to be
removed.
Controller
Cord clamp base
Carbon brush
Spiral spring
Spiral spring
Carbon brush
Carbon brush
P 11/ 19
Handle section
4x18 Tapping screw (2pcs.)