T7100F MICROELECTRONIC CONVENTIONAL OR HEAT PUMP THERMOSTAT
Test
Key to
Mode
Press
Number
Heating Equipment Self-Test
i
10
11
12
13
12
11
10
Emergency Heating Equipment Self-Test (with select Q7100C Subbase models)
20
i
21
20
Cooling Equipment Self-Test
30
i
31
32
31
30
Fan Equipment Self-Test
40
i
41
40
a
KEY TEST
60
i
60
60
Override
60
a
System
60
a
Fan
60
a
Available on select models.

Thermostat Information

1. Press the Information i key to access the thermo-
stat information.
69-0964–2
Table 4. Installer Self-Test Options.
Enter heating equipment Self-Test.
Stage-one heat comes on. When Installer Setup mode number 01 is 01 or mode number 02
is 01, the system fan is also energized.
Stage-two heat comes on. Stage-one heat and system fan remain on.
Stage-three heat comes on (heat pump configuration). Stage-one and stage-two heat remain
on.
Stage-three heat turns off.
Stage-two heat turns off.
Stage-one heat and system fan turn off.
Change from heating to emergency heating equipment Self-Test.
Emergency heat comes on.
Emergency heat turns off.
Change from heating or emergency heating to cooling equipment self-test.
Stage-one cooling and system fan come on.
Stage-two cool comes on. Stage-one cool and system fan remain on.
Stage-two cool turns off.
Stage-one cool and system fan turn off.
Change from cooling to fan equipment Self-Test.
Fan comes on.
Fan turns off.
Displays 2.
Displays 4.
Displays 3.
Displays 5.
Displays 0.
Displays 1.
M4864
Description
2. Press the increase
date code. The first two large digits are the month
and the third digit is the last digit of the year.
(Example: 026 = February 1996)