3) Push the front panel lever of the interface board until the board is completely inserted
into the OfficeServ 7200-S slot.
3.3.2 Replacing Boards
If the OfficeServ 7200-S system fails to operate normally due to an error on the power supply
board, control board, or interface board, replace the board with a new one.
Removing Cables
Replace a board after removing all cables connected to the board.
The procedure for replacing a board installed in a slot of a cabinet is as follows:
POWER TO THE CABINET MUST BE TURNED OFF. Failure to do so will damage the
card, cabinet and/or corrupt the data moving along the data bus.
1) Turn off the power of the cabinet.