English-16
It is possible to switch from all recording modes to linear recording mode by applying an
alarm signal to the SET terminal on the rear panel.
*
Set the alarm recording mode and alarm recording period with alarm set up of menu.
*
The index signal is automatically recorded when an alarm recording begins.
Buzzer is activated while alarm recording when the alarm signal is input, if the buzzer is
set ON on the picture of ALARM SET.
*
In case when another alarm signal is input into ALARM IN TERMINAL while the index
signal is recorded,
-Input within 1 min. : Recording is newly started without indicating alarm listing any more.
-Input after 1 min. : Recording is newly started with new starting time indicated on the
alarm listing.
*
When an alarm signal is input during alarm video tape recording it is executed based on
the last input alarm signal.
ALARM RECORDING CONNECTION

ALARM RECORDING

ALARM SIGNAL
* It is possible to switch the alarm
recording by applying the set signal
from the alarm sensor during
recording in all time mode.
*
The alarm can be confirmed
from a distance. Because buzzer
sounds when external alarm
signal is input.