SWEEP
This softkey lets you set a sweep time for frequency sweeps or power
sweeps. The sweep time range is 10 ms to 2OOs, but the fastest sweep
time is constrained by the frequency span. The fastest possible sweep
can be determined automatically:
1. Press SWEEP (MENU), this reveals the sweep menu keys.
synthesizer calculates the fastest possible calibrated sweep time for
any
sweep span.
Whenever you press (SWEEPTIME), the active entry area displays
the current sweep time and whether the sweep time is coupled to
the frequency span (far right hand side displays:
AUTO is not displayed then the sweep time auto function is off.
SCPI: SWEep[:FREQ uency]:TIME <num>[time suffix] or
Analyzer: ST <num> [sclms]
Power Sweep
"Power Level and Sweep Time Operation," in Chapter 1.