Mitsubishi Electric MXZ-SM72TAM-U1 Service Manual page 34

Hide thumbs Also See for MXZ-SM72TAM-U1:
Table of Contents

Advertisement

Error
Error
code
code
(2 digits)
(4 digits)
U3
5101
U4
5102
U4
5103
U4
5105
U4
5106
U4
5109
U4
5110
F5
5201
F3
5202
UH
5300
P4
5701
A0
6600
A2
6602
A3
6603
A6
6606
A7
6607
A8
6608
E0/E4
6831
E3/E5
6832
E3/E5
6833
E0/E4
6834
EF
7100
EF
7101
EF
7102
EF
7105
EF
7130
Notes:
• When the outdoor unit detects No ACK error/No response error, the target indoor unit is treated as a stop, and not assumed to be abnormal.
• The error codes displayed on the units may be different between the error source and others. In that case, please refer to the error code of error source
by displayed attribute and address.
• Refer to the service manual of indoor unit or remote controller for the detail of error detected in indoor unit or remote controller.
■ Self-diagnosis function
The indoor and outdoor units can be diagnosed automatically using the self-diagnosis switch (SW1) and LED1, LED2 (LED
indication) found on the outdoor multi controller circuit board.
LED indication: Set all contacts of SW1 to OFF.
■ During normal operation
The LED indicates the drive state of the controller in the outdoor unit.
Bit
Compressor
Indication
operated
• Example
When the compressor and SV1 are on during cooling operation.
1 2 3 4 5 6 7 8
OCH800A_34
Trouble
Air inlet thermistor (TH21) open/short
Compressor temperature thermistor (TH4) open/short
Liquid pipe temperature thermistor (TH22) open/short
Suction pipe temperature thermistor (TH6) open/short
Gas pipe temperature thermistor (TH23) open/short
Outdoor liquid pipe temperature thermistor (TH3)
open/short
Ambient temperature thermistor (TH7) open/short
HIC pipe temperature thermistor (TH2) open/short
Heat sink temperature thermistor (TH8) open/short
High pressure sensor (63HS) trouble
Low pressure sensor (63LS) trouble
Primary current error
Contact failure of drain float switch
Duplex address error
Transmission processor hardware error
Transmission bus BUSY error
Signal communication error with transmission proces-
sor
No ACK error
No response frame error
MA communication receive error
MA communication send error
MA communication send error
MA communication receive error
Total capacity error
Capacity code error
Connecting excessive number of units and branch
boxes
Address setting error
Incompatible unit combination
1
2
3
52C
21S4
Detected Unit
Remote
Indoor
Outdoor
Controller
О
О
О
О
О
О
О
О
О
О
О
О
О
О
О
О
О
О
О
О
О
О
О
О
О
О
О
О
О
О
О
О
О
О
О
О
О
О
О
О
О
О
О
4
5
6
SV1
(SV2)
SV3
Remarks
Check delay code 1202
Check delay code 1211
Check delay code 1205
Check delay code 1221
Check delay code 1222
Check delay code 1214
Check delay code 1402
Check delay code 1400
Check delay code 4310
Only M-NET Remote controller is detected.
Only M-NET Remote controller is detected.
Only M-NET Remote controller is detected.
Only M-NET Remote controller is detected.
Only M-NET Remote controller is detected.
Only M-NET Remote controller is detected.
Only MA Remote controller is detected.
Only MA Remote controller is detected.
Only MA Remote controller is detected.
Only MA Remote controller is detected.
7
8
Always lit

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mxz-sm96tam-u1Mxz-sm120tam-u1

Table of Contents