5-11.
3.7 GHz OSCILLATOR, A8
NOTE
This procedure
is
provided primarily for those cases when the
A8A1
circuit
board has been repaired or replaced.
Reference
Performance
Test:
None
Service Section
RF Section
(Power
Level Control)
Description
This
procedure
monitors the output current of the 100
MHz
RF Amplifier that
provides the LO signal
for the sampler and adjusts for maximum output. The oscillator phase-lock loop
is
then opened by
removing jumper A8E3 and the balance
is
adjusted at the output of the
sampler to obtain
a
symetrlcal
square wave of approximately 35
Volts
peak-to-peak
to drive the phase-lock amplifier.
OSCILLOSCOPE
DIGITAL
VOLTMETER
A8R4
NOTE
ONLY
MAKE FEST
EQUIPMENT CONNECI-IONS AS DIRECTED
IN
THE
PROCEDURE.
Figure 5-33.
A8 3.7 GHz
Osctftotor Test Setup