Sensor Module Cabinet Smc30; Sensor Module Cabinet Smc40 - Siemens Sinamics s120 Commissioning Manual

With starter
Hide thumbs Also See for Sinamics s120:
Table of Contents

Advertisement

Diagnostics
4.1 Diagnostics via LEDs
4.1.3.3

Sensor Module Cabinet SMC30

Table 4- 35
Meaning of LEDs on the Sensor Module Cabinet SMC30
LED
Color
RDY
READY
Green
Orange
Red
Green/red
Green/red
Green/
orange
or
Red/orange
OUT > 5
V
Orange
The parameters for activating component recognition using LEDs can be taken from the following reference:
1)
Reference: /LH1/ SINAMICS S120/S150 List Manual
4.1.3.4

Sensor Module Cabinet SMC40

Table 4- 36
Meaning of the LEDs on the Sensor Module Cabinet-Mounted SMC40
LED
Color
Status
RDY
Off
READY
Green
Continuous
light
Orange
Continuous
light
Red
Continuous
light
328
Status
Description, cause
Off
The electronics power supply is missing or outside the per-
missible tolerance range.
Continu-
The component is ready for operation. Cyclic DRIVE-CLiQ
ous light
communication is taking place.
Continu-
DRIVE-CLiQ communication is being established.
ous light
Continu-
This component has at least one fault.
ous light
Note:
LED is controlled irrespective of the corresponding messag-
es being reconfigured.
Flashing
Firmware is being downloaded.
light 0.5
Hz
Flashing
Firmware download is complete. The system waits for
light 2 Hz
POWER ON.
Flashing
Component recognition via LED is activated
light
Note:
Both options depend on the LED status when component
recognition is activated.
Off
The electronic power supply is missing or outside permissi-
ble tolerance range.
Power supply ≤ 5 V.
Continu-
The electronics power supply for the encoder system is
ous light
available.
Power supply > 5 V
Description, cause
The electronics power supply is missing or outside the per-
missible tolerance range.
The component is ready for operation. Cyclic DRIVE-CLiQ
communication is taking place.
DRIVE-CLiQ communication is being established.
This component has at least one fault.
Note:
LED is controlled irrespective of the corresponding messag-
es being reconfigured.
.
1)
STARTER Commissioning Manual
Commissioning Manual, (IH1), 07/2016, 6SL3097-4AF00-0BP5
Remedy
Remedy and
acknowledge fault
Carry out a POWER
ON
Remedy
Remove and
acknowledge the fault.

Advertisement

Table of Contents
loading

Table of Contents