Description of the LED states of a CU320-2
The various states of the Control Units CU320-2 DP and CU320-2 PN during power-up and
during operation are displayed using LEDs on the Control Unit. The duration of the individual
statuses varies.
Table 4- 1
LED
RDY
DP/PN
OPT
● If an error occurs, the booting procedure is terminated and the cause is indicated
accordingly via the LEDs.
● Once the unit has successfully booted up, all the LEDs are switched off briefly.
● Once the unit has booted up, the LEDs are controlled via the loaded software.
Control Unit 320-2 DP while powering up
Table 4- 2
Red flashing
light 2 Hz
Red flashing
light 2 Hz
306
LEDs
Function
Ready
PROFIdrive cyclic operation via PROFIBUS (DP) or PROFINET (PN)
OPTION
Load software
LED
RDY
DP
Red
Orange
Red
Red
Red
Red
Flashing
light 2 Hz
Red
Orange
flashing
light
Red
Off
State
OPT
Orange
Reset
Off
BIOS loaded –
Off
BIOS error
Off
File error
Off
FW loading
Off
FW loaded
Commissioning Manual, (IH1), 07/2016, 6SL3097-4AF00-0BP5
Comment
Hardware reset
RDY LED lights up red, all other LEDs light
up orange
Error occurred while loading the BIOS
•
Memory card not inserted or faulty
•
Software on memory card not present
•
or corrupted
RDY LED lights up red, PN LED flashes
orange without fixed frequency
–