Sharp IV-S20 User Manual page 84

Compact image sensor camera
Table of Contents

Advertisement

Installation Conditions and Method
Ë When using the IV-60LD
This paragraph describes how to use Sharp IV-60LD LED lighting equipment. For details about the
installation and wiring of the IV-60LD, see the instruction manual.
The distance between the IV-60LD and an object (distance at which to install lighting equipment) should be
approximately 150mm, and the lit area is approximately 50mm × 50mm.
If the lighting distance is reduced approximately 60mm, the lighting may be uneven.
∫ View A
6
When the light is projected from above the object and if reflection off the object influences the image
processing, try the following countermeasures.
1Tilt the camera center axis (within a range that does not affect the image processing) to move away
from the light reflected from the object.
2Separate the camera from the lighting equipment. Install the IV-60LD lighting equipment so that it will
shines from an angle that prevents creation of the reflection.
- One light
IV-S20 camera
IV-S20 camera
Camera angle bracket
IV-60LD body
(Lighting section)
Light area
Camera center
50mm
yyy
Workpieces
(Object to be
measured)
yy
IV-60LD body
77.3mm
Camera center
A
Workpieces
(Object to be
measured)
IV-S20 camera
IV-60LD body
Reflected light
- Two lights
yy
IV-60LD body
6-2
IV-S20 camera
IV-60LD body

Advertisement