Sharp IV-S20 User Manual page 384

Compact image sensor camera
Table of Contents

Advertisement

Detalis about the improved functions in software version 2.0 (compared with version 1.6)
Item
High speed
- Improved processing speed (from 55ms in version 1.6 to
37ms in version 2.0), when the search area is 256 × 256,
a 64 × 64 model is used, and the reduction ratio is 3.
- Processing speed improved approximately 60%, for the
Gray search
large model size.
Gray search line can be used
Register a reference image from external equipment
Detection coordinates can be set at any position
Gray search precision level can be set independently for
each reference image
Lines and rectangles can both be detected
Center point detection can both be detected
Edge detection
Increased number of edge detection directions to 4:
Horizontal (-, =), vertical (] [)
Artifact processing added
Ability to assign X axis correction and Y axis correction
Measurement of
independently for a two-point search.
positional
deviation
Rotation correction function added
Function to count quantities was added (up to 3000 items,
including an area filter)
Increased number of object identification before area filter
Binary conversion
(3000 objects)
measurement
Ellipse window added
Binary conversion pre-processing available for each
window
Point
Verification using average density is possible
measurement
Added lead length inspection function
Lead inspection
Display maximum and minimum values
Display NG positions
Added AND STR and OR STR operation instructions
Check for doubled use of the same instruction
Added list of functions used and execution monitor
PC functions
Direct Y output and auxiliary relay for evaluation result
added, also numeric value calculations.
Added output of final evaluation result (C112) and
continuous trigger relay (C113)
Square root, absolute value, TAN, and ATAN calculation
functions are added
Numerical
calculations
Added final numerical calculation function
Load and save displayed image
General-purpose
Communication function between another IV module
serial input
(for creating a clone)
Computer link
Assignable output block as well as block 0
To the next page
Ver. 2.0
Appendix-5
Ver. 1.6 or earlier
Rectangles only
Not available
Limited to the center of the
reference image
Could only be set for each
emasurement
Rectangles only
Not available
Two directions
Horizontal (-), vertical (])
Not available
Only simultaneous correction of X
and Y axes.
Not available
Up to 128 objects
Up to 128 objects
Only rectangle and circle
Settable only for each
measurement
Density after binary conversion
only
Lead pitch only
Average value only
No display
No check
No monitor
Needed to create a ladder program.
Only numerical calculation for each
measurement
Save only
Not available
Block 0 only

Advertisement