[Procedure 3]
Does the tray go up?
NO Æ
l
l
l
l
l
l
l
l
l
l
l
l
È
YES
Is the shift motor clock sensor (PI7) working properly?
YES Æ Replace the finisher controller PC boar
È
NO
Replace the sensor.
[CB50] Staple motor abnormality
MJ-1025
[Procedure 1]
Is the wiring between the finisher controller PC board and the staple/fold motor normal?
NO Æ
È
YES
Try to rotate the staple jam releasing dial. Is there mechanical trapping?
YES Æ Fix the mechanism.
È
NO
Try replacing the staple/fold motor (M7). Is the problem corrected?
YES Æ End.
È
NO
Replace the finisher controller PC board.
e-STUDIO200L/202L/230/232/280/282 TROUBLESHOOTING
Is 24 VDC supplied from the finisher controller PCB to the shift motor as
soon as the tray is driven?
NO Æ
Replace the finisher controller PC board.
È
YES
Is there any problem with the tray up/down mechanism?
YES Æ Fix the lift mechanism.
È
NO
Replace the shift motor.
Correct the wiring.