Notes:
The digit after the hyphen in "Code" of the following table is a sub code.
e-STUDIO200L/230/280: In "RAM", the NVRAM of the board in which the data of each code
Classifi-
Code
cation
200
General
Date and time setting
201
General
Destination selection
202
User
Counter installed externally
interface
203
General
Line adjustment mode
204
User
Auto-clear timer setting
interface
205
User
Auto power save mode
interface
timer setting
June 2004 © TOSHIBA TEC
is stored is indicated. "M" stands for the LGC board, "SYS" and
"UTY" stands for the SYS board and "NIC" stands for the NIC
board.
Setting mode (08) <e-STUDIO200L/230/280>
Default
Func-
<Accept-
Items
tion
value>
ALL
<13 dig-
ALL
EUR: 0
ALL
ALL
ALL
<0-10>
ALL
EUR: 11
Others:
<0, 6-15>
e-STUDIO200L/202L/230/232/280/282 ERROR CODE AND SELF-DIAGNOSTIC MODE
2 - 85
05/12
RAM
Contents
able
-
-
Year/month/date/day/
hour/minute/second
its>
Example:
03 07 0 13 13 27 48
"Day" - "0" is for
"Sunday". Pro-
ceeds Monday
through Saturday
from "1" to "6".
M
0: EUR
UC: 1
1: UC
JPN: 2
2: JPN
<0-2>
0
M
0: No external counter
<0-3>
1: Coin controller
2: Copy key card
3: Key copy counter
0
M
0: For factory shipment
<0-1>
1: For line
*
Field: "0" must be
selected
3
SYS
Timer to return the
equipment to the
default settings when
the [START] button is
not pressed after the
function and the mode
are set
0: Not cleared
1 to 10: Set number x
15 sec.
SYS
Timer to automatically
UC: 11
switch to the Auto
JPN: 6
power save mode when
the equipment has not
11
been used
0: Invalid
7: 4min.
9: 7min.
10: 10min.
11: 15min.
12: 20min.
13: 30min.
14: 45min.
15: 60min.
Proce-
dure
5
1
1
1
1
1
6: 3min.
8: 5min.
2