216 en | Configuration
DCN-FMIC
DCN-FLSP
DCN-FLSP
Figure 7.24 Ambient microphone mode (7)
7.13
DCN-FMIC Microphone Connection Panel
Use the solder spot to enable or disable the green LED ring of the connected DCN-MICL or
DCN-MICS Pluggable Microphone (refer also to Section 8.11 DCN-MICL, DCN-MICS Pluggable
Microphones).
Solder spot
Not soldered*
Soldered
Table 7.34 Solder spot (* = default)
When the microphone connection panel is connected to a dual delegate interface that is in the
dual delegate with one microphone mode, you must disable the green LED ring. If you do not
disable the LED ring, the LED ring of the connected microphone cannot show the correct
condition. For example, first delegate 1 enables the microphone (red) and then delegate 2
makes a request-to-speak (green). Although the microphone is enabled, the green LED ring
comes on when delegate 2 pushes the microphone button.