Table 6- 28
Technical data of the dV/dt filter plus voltage peak limiter, 3 AC 500 ... 690 V, Part 3
Order number
Suitable for Motor Module
Type rating of the Motor
Module
I
thmax
Degree of protection
dV/dt reactor
Power loss
- At 50 Hz
- At 60 Hz
- At 150 Hz
Connections
- To the Motor Module
- Load
- PE
Max. permissible cable
length between dV/dt
reactor and motor
Dimensions
Width
Height
Depth
Weight, approx.
Voltage peak limiter
Power loss
- At 50 Hz
- At 60 Hz
- At 150 Hz
Connections
- To the dV/dt reactor
- DC
- PE
Dimensions
Width
Height
Depth
Weight, approx.
Two dV/dt reactors are required for these dV/dt filters. The technical data provided applies to one dV/dt reactor.
1)
Note
Cable lengths for versions with two dV/dt reactors
For versions with 2 dV/dt reactors, the cable lengths specified in the table do not change.
Chassis power units
Manual, (GH3), 01/2013, 6SL3097-4AE00-0BP3
6SL3000-
2DH34-1AA0
6SL3320-
1TG34-1AAx
kW
400
A
410
IP00
kW
0.786
kW
0.826
kW
0.884
M12
M12
M6
m
mm
460
mm
385
mm
312
kg
147
kW
0.051
kW
0.048
kW
0.043
M8
M8
M8
mm
309
mm
1312.5
mm
400
kg
48
Motor-side power components
6.3 dv/dt filter plus Voltage Peak Limiter
2DH35-8AA0
2DH35-8AA0
1TG34-7AAx
1TG35-8AAx
450
575
IP00
IP00
0.862
0.862
0.902
0.902
0.964
0.964
M12
M12
M6
300 (shielded)
450 (unshielded)
460
385
312
172
0.063
0.063
0.059
0.059
0.054
0.054
M8
M8
M8
309
1312.5
1312.5
400
48
2DH38-1AA0
1TG37-4AAx
560
710
575
810
IP00
0.828
0.867
0.927
M12
2 x M12
M12
2 x M12
M6
M6
460
445
385
385
312
312
172
160
0.106
0.1
0.091
M8
M10
M8
M10
M8
M8
309
309
1312.5
400
400
48
72
1)
281