Toshiba e-STUDIO453 Service Manual page 214

Hide thumbs Also See for e-STUDIO453:
Table of Contents

Advertisement

Notes:
1. When installing, make sure that the pressure
of cleaning blade is released with the jig.
2. Insert the head of the jig to the space shown
in the figure while pushing the blade holder.
3. Be careful not to touch or scratch the edge of
cleaning blade.
[D] Cleaner
(D-1) Cleaning blade
(1) Take off the cleaner unit. Then take off the
main charger and drum (
(B-1) [C]).
(2) Remove 2 screws and cleaning blade.
11
Note:
Pay attention to the following points when install-
ing the cleaning blade.
1. Do not touch the end face of the cleaning blade
and not make a scratch or similar.
2. The cleaning blade should not contact with the
seals. (2 places)
3. If it contacts, shift the screw from A to B and
adjust it so as not to contact with the seals.
e-STUDIO350/352/353/450/452/453
DRUM RELATED SECTION
Chapter 11.6 [A]
© 2003 - 2008 TOSHIBA TEC CORPORATION All rights reserved
 - 2
07/06
Fig. 11-613
Fig. 11-614
A
B
Cleaning blade
Seal
Fig. 11-615