Hitachi WJ200 Series Instruction Manual page 385

Wj200 series single-phase input 200v class three-phase input 200v class three-phase input 400v class
Hide thumbs Also See for WJ200 Series:
Table of Contents

Advertisement

C−4
Func.
Code
[O] input active range end
A014
voltage
[O] input start frequency
A015
enable
Analog input filter
A016
A017
Multi-speed operation
a019
selection
Multi-speed freq. 0
A020
Multi-speed freq. 0,
A220
2
nd
motor
Multi-speed freq. 1 to 15
A021
(for both motors)
to
A035
Jog frequency
A038
Jog stop mode
A039
Torque boost select
A041
"A" Function
Name
The ending point (offset) for the
active analog input range,
range is 0. to 100.
Two options; select codes:
00...Use offset (A011 value)
01...Use 0Hz
Range n = 1 to 31,
1 to 30 : ×2ms filter
31: 500ms fixed filter with ±
0.1kHz hys.
Select codes:
00...Binary operation (16 speeds
01...Bit operation (8 speeds
Defines the first speed of a
multi-speed profile, range is 0.0
/ start frequency to 400Hz
A020 = Speed 0 (1st motor)
Defines the first speed of a
multi-speed profile or a 2nd
motor, range is 0.0 / start
frequency to 400Hz
A220 = Speed 0 (2nd motor)
Defines 15 more speeds,
range is 0.0 / start frequency to
400 Hz.
A021=Speed 1 ~ A035=Speed15
A021 ~ A035
Defines limited speed for jog,
range is from start frequency to
9.99 Hz
Define how end of jog stops the
motor; six options:
00...Free-run stop (invalid
01...Controlled deceleration
02...DC braking to stop(invalid
03...Free-run stop (valid during
04...Controlled deceleration
05...DC braking to stop(valid
Two options:
00...Manual torque boost
Description
selectable with 4 terminals)
selectable with 7
terminals)
during run)
(invalid during run)
during run)
run)
(valid during run)
during run)
Run
Defaults
Mode
Lnitial data
Units
Edit
100.
%
01
8.
Spl.
00
-
00
-
0.0
Hz
0.0
Hz
See next
Hz
row
0.0
Hz
6.00
Hz
04
00

Advertisement

Table of Contents
loading

Table of Contents