Jump Frequencies - Hitachi WJ200 Series Instruction Manual

Wj200 series single-phase input 200v class three-phase input 200v class three-phase input 400v class
Hide thumbs Also See for WJ200 Series:
Table of Contents

Advertisement

Jump Frequencies – Some motors or machines exhibit resonances at particular
speed(s), which can be destructive for prolonged running at those speeds. The inverter
has up to three
jump frequencies causes the inverter output to skip around the sensitive frequency
values.
Output
frequency
A067
A065
A063
Func.
Name
Code
Jump freq. (center) 1 to 3
A063
A065
A067
Jump freq. width
A064
(hysteresis) 1 to 3
A066
A068

jump frequencies

as shown in the graph. The hysteresis around the
A064
A064
"A" Function
Up to 3 output frequencies can
be defined for the output to
jump past to avoid motor
resonances (center frequency)
Range is 0.0 to 400.0 Hz
Defines the distance from the
center frequency at which the
jump around occurs
Range is 0.0 to 10.0 Hz
A068
A068
A066
A066
Frequency
command
Description
Run
Defaults
Mode
Lnitial data
Units
Edit
0.0
Hz
0.0
0.0
Hz
0.5
0.5
0.5
3−29