Panasonic MEW01349 Operating Instructions Manual page 90

Fire alarm system
Table of Contents

Advertisement

Panasonic Electric Works Nordic AB
MEW01349
Write zone numbers
(e.g. 001, 002, 003,
004)
""
The zone(s) will stay in test mode until the test mode is ended but after 60 minutes or if you press "Esc
menu", you will be logged out from menu H1.
Perform the test as quickly as possible, since the output(s) for routing equipment (fire brigade tx) are disabled
(also the parts of the zones in test mode, not visible for the test personnel, are disabled).
In order to shorten the testing time, any time delay for the detectors / zones in test mode will be "disabled",
i.e. fire alarm will be detected faster than normally.
In the tested alarm point, the LED will light up, and the LEDs "Fire" (L1) in the c.i.e. will light up approx. 10
seconds, then the alarm point will be automatically reset. The printer, if available, will print out every tested
alarm point (Zone: xxx Address: xx Time: HH.MM).
A sensor in test mode will not be able to activate fault.
After 60 minutes or
"Esc Menu"
(When required:
"Menu", "code")
"↲ "
Some national regulations also require a routine test of the routing equipment.
Press press "↵ " (i.e. select "No") for no test. If so, the monthly test is completed (see below).
or
Press "▼" and "↵ " (i.e. select "Yes") to start such a test. If so, the following will happen in the system:
 The c.i.e. "Fault tx" output will be de-activated (note that this output is activated in normal state),
indicated by the LED "Fault tx activated" (L13).
60 seconds count-down starts.
 After 30 seconds, also the c.i.e. "Fire brigade tx" output (and corresponding programmable outputs
type "routing equipment") will be activated, indicated by the LED "Fire brigade tx delay" (L14).
 After another 30 seconds, the test will be ended and the outputs and LEDs will return to "normal".
"▼" and "↲ "
"↲ "
Rev: -
Operating Instructions Fire alarm system EBL512 G3, V1.1.x
Zones to be set in test mode
001 002 003 004
Zones in test mode:
End test: 
001 002 003 004
Zones in test mode:
End test: 
001 002 003 004
(
NOTE! See chapter "The information area priority
order", page 22 regarding priority order.)
Zones in test mode:
End test: 
001 002 003 004
Please wait....
Test of routing equipment?
Test of routing equipment in progress.
nnn seconds left.
Monthly test is completed!
Press 
▒▒▒ menu
No
Yes
88
Press "↵ " to start the test
mode.
LED "Test mode" (L8)
will light up. Perform the
tests.
You are no longer in menu
H1 but still in test mode.
Press "
" to end test.
The LED "Test mode" is
turned OFF.
"nn" starts at 060 and will
count down to 000.
Scroll to another menu or