devices. To prevent damage, observe antistatic precautions.
CAUTION:
CAUTION:
The port blank provides EMI shielding and helps maintain proper thermal status inside the server. Do not operate the
server when a port blank is removed without the corresponding I/O port option installed.
Prerequisites
Prerequisites
Before you perform this procedure, make sure that you have the following items available:
T-15 Torx screwdriver
Phillips No. 1 screwdriver
4.5 mm hex nut screwdriver
Procedure
Procedure
1. Power down the server.
2. Remove all power:
a. Disconnect each power cord from the power source.
b. Disconnect each power cord from the server.
3. Disconnect all peripheral cables from the server.
4. Do one of the following:
If the server is in tower mode, place the server on a flat, level surface with the access panel facing up.
If the server is in rack mode, remove the server from the rack .
5. Remove the access panel .
6. If installed, remove the air baffle .
7. If installed, disconnect the serial port cable from the module .
8. If installed, remove the M.2 SSD .
9. Remove the iLO-M.2-serial module:
a. Remove the module stabilizer.
HPE ProLiant ML30 Gen10 Plus Server Maintenance and Service Guide
87