Setup & Operation 8. I/O Remote Settings
8.3.6 Timing Diagram for RECOVER Sequence (EPSON RC+)
Remote Auto Recover
Paused
Output
SafeGuard
Output
RecoverReqd
Output
RecoverInCycle
Output
Safety Input
Input
Latch Input
Input
Recover
Input
Start
Input
92
22
6
21
25
11
20
18
RC520 Rev.7
[Unit: msec]