Electrical connection
<Without weld process monitoring>
7-34
PST 6101.321 / PSI 6101.321
This signal indicates that welding is performed without current monitoring.
If current monitoring is switched off, deviations from the tolerance band in current moni-
toring are not detected.
NOTE
When weld process monitoring has been deactivated, you should always check the qual-
ity of your welds.
Current
Monitoring stopped
monitoring
off
off
on
on
Figure 27: Monitoring
NOTE
Monitoring stopped is activated and deactivated for all timers (for all programs of the
selected timer) in the Basic-Setup, in the menu Sequence-Setup.
Current monitoring is activated and deactivated for specific programs with the Welding
Parameters option in the Current-Monitoring window.
for all timers
on
on: without monitoring
off
on
off
Weld process monitoring function
on: without monitoring
on: without monitoring
off: with monitoring