Bosch PST 6101.321 Technical Information page 71

Timer and i/o level
Table of Contents

Advertisement

Electrical connection
<Reset "Electrodes have been replaced">
7-28
PST 6101.321 / PSI 6101.321
The timer signals the <End of Stepper>. Any further [sequences] can be disabled in the
timer. This signal will be reset and turned off as soon as a <Reset "Electrodes have
been replaced"> signal reports, that the electrodes have been replaced.
NOTE
If program number 0 (= electrode number 0) is selected with the Program selection si-
gnals and an Electrode replaced signal becomes high, the tip dress and wear counters of
all electrodes will be reset.
If a program number (= electrode number 1 to n, n = maximum number of electrodes) is
selected with the Program selection signals and an Electrode replaced signal becomes
high, the tip dress and wear counters are reset for the electrode selected by the number of
the Program selection signals.
Influencing the wear counter with the input signals:
Figure 24: Influencing the wear and tip dress counters using the electrode replaced signal
(Program selection / Electrode-no.)
+
Electrode replaced
=
- Wear
- Tip dress counter
Õ 0
Õ 0
1070 080 056-101 (99.09) GB