Bosch PST 6101.321 Technical Information page 34

Timer and i/o level
Table of Contents

Advertisement

!
1070 080 056-101 (99.09) GB
PST 6101.321 / PSI 6101.321
[1]
Line LED, mains voltage (PST) or d.c. link voltage (PSI) is present.
[2]
Ready LED
timer ready, turns off in case of:
-
Internal fault, e.g. dead battery
-
Schedule fault, e.g. no current.
[3]
Firing LED, Control signal for thyristor unit active
[4]
Battery fault LED, backup battery voltage too low
[5]
Reset push button, clears pending fault messages, returns timer to ready state.
[6]
DIL switch, to set up address of field bus interface (no function with
INTERBUS PMS).
LED red, operating mode timer processor:
[7]
-
On
: timer stopped processing commands
timer is in boot mode.
-
Off
: timer is in operating mode.
[8]
Recessed key, switching from operating mode to boot mode.
Pressing this key turns the system to boot mode.
D
You should only turn to boot mode for loading a new operating program (firmware).
CAUTION!
This key may only be operated by authorized personnel.
Never operate this key during a welding operation.
Program execution will be stopped and all control outputs set to zero.
[9]
9-pin D shell plug, V24 interface (programming terminal).
[10]
14-pin plug-in terminal - power supply:
-
+24 V supply
-
external
-
standby
-
stop circuit
-
+24 V supply I/O
[11]
2-pin plug-in terminal power supply external device.
[12]
3-pin plug-in terminal (no function).
[13]
5-pin plug-in terminal analog pressure output, voltage from 0 V to +10 VDC, max.
20 mA (drives pressure regulating valve).
Hardware
3-3

Advertisement

Table of Contents
loading

This manual is also suitable for:

Psi 6101.321