Configuration; Data Layout - Bosch DCN Manual

Table of Contents

Advertisement

External Interface Manual
3.4.2

Configuration

This output is enabled by the "Error logging to Aux" option in the Startup application. By default it uses COM-
port 1 on the local PC, but it can be routed to any COM-port or even to a different PC by adding the following
section to DCN.INI:
[ErrorLogging]
ComPort=X
ComPortPCID=NR
See section 3.2.2 for the description of these fields.
3.4.3

Data layout

Each error produces a short ASCII string terminated by a carriage return and newline character.
The string has the following layout:
<action code><state><error code>
where:
action code
state
error code
Note: The layout of this output is identical to the Microphone Activity logging layout. This is
intentional, to make processing of the data produced on these outputs easier if both outputs are
routed to the same COM-port.
Bosch Security Systems B.V. | 2004 April | External Interface Manual
%
It is an error
1
Default (no special meaning)
The 'error code' is a 4-digit hexadecimal number that indicates
which error has occurred and can have the following values:
1701
CCU not available
3201
Slave CCU connected (multi-CCU only)
3202
Slave CCU disconnected (multi-CCU only)
3208
Unit disconnected
en | 19

Advertisement