4.3.4. Memory protection function "prot"
The memory protection function protects the selected memory from being overwritten.
When this function is initiated copying data to the memory is prohibited. Reading the memory data is
permitted.
When all the memories are initialized by memory initialization function (clr), the LED indications
are as follows:
"in", "a", "b", "c" = "off", "sup" = "on"
This is also the default setting at the time of shipment.
Operating procedure
Key
LED indication
→
"copy"
"com
→
p"
SFT
"prot"
→
ENT
"prot"
"in"
→
→
"in"
"a"
→
→
"c"
"sup"
SFT
"in"
→
"in"
"off"
ENT
→
"in"
"on"
→
"off"
"on"
SFT
→
"off"
→
ENT
"on"
"prot"
ed, Remote Keypad returns to previous status (except when executing).
- If the [ESC] key is press
(*1) The Protecting operation of " sup " is different from that provided for other memories and is shown below.
With the same inverter types
(capacity, voltage class)
supStandard parameters Special parameters
on
off
" ": Protection disabled (write permitted),
(*2) In this case, copying operation of p
class.
< Selecting a desired function >
Select "prot" (memory protection function) with the [SFT] key.
< Entering the selected function >
After selecting "prot" with the [SFT] key, press the [ENT] key and "in"
(selecting inverter memory) appears in the display window.
< Selecting a memory to protect its data >
Each time the [SFT] key is pressed, the display changes as follow
" in"
selecting inverter memory
"b"
" a"
selecting memory A
→
" b"
selecting memory B
" c"
selecting memory C
"sup"
special parameter selection
and to "in" again in this order.
< Entering the memory to protect its data >
After selecting "in" (selecting inverter memory, by way of example) with the
[SFT] key, press the [ENT] key and the display shows the present memory
protection status. (When "on" appears on the display, the selected memory
is protected. When "off" appears on the display, the selected memory is
not protected.)
< Protecting the selected memory >
Each time the [SFT] key is pressed, the indication in the display changes
"on"
protecting the selected memory (write prohibited)
"off" canceling protection of the selected memory (write permitted)
alternately.
< Executing protection of the selected memory >
After selecting "on" (protecting the selected memory, by way of example) with
the [SFT]key, press the [ENT]key. Remote Keypad starts protecting the
selected memory (canceling the protection in case of "off") and the
indication in the display window returns to "prot".
–
arameters from one inverter to another inverter of a different capacity or a different voltage
Key operation and description
(
1)
*
With different inverter types
(capacity, voltage class)
sup
Standard parameters Special parameters
on
off
–
(
2)
*
"–": Write protected (write prohibited)
13
E6581277
–
–