7.3. Warning indications

Warning indications: Indicated by flashing LED display.
Warning Code
LED
display
The target memory to copy data or to initialize is write protected. Copying any data to
prot PROT
the memory or initializing the memory cannot be executed. Press the [ESC] key to
cancel.
The type of device is different (different in series or voltage class or capacity of inverter).
Press the [ENT] key to copy between two inverters of different capacity or voltage class.
Press the [ESC] key to cancel copying. If "sup" (system area parameters) protection
has been disabled by setting "prot"(memory protection) to "off", the copying
deVe DEVE
cannot be executed even if the [ENT] key is pressed. Copying to the inverter of a
different series is impossible.
After copying between two inverters with different capacities, the type information
parameters depending on the inverter capacity or voltage class should be initialized. See
the inverter instruction manual on how to initialize them.
Indicated memory is not found or has been corrupted.
erRa
This indication appears when memory A, B, or C is selected to copy data from, to
ERRA
compare data to, or to protect data, but no data can be found in the selected memory
erRb
ERRB
(including the case when power was turned off during the previous copying operation),
ERRC
erRc
or a CRC code error occurred in the selected memory. Press the [ESC] key to cancel.
In this case the data has to be rewritten.
Indicates the title number of the parameter that was found to be different while using
comparison function, or that cannot be written while using the copying function. Press
the [ENT] key to continue, the [ESC] key to cancel.
When Remote Keypad did not find any data in one memory, it flashes "%" in case the
data is missing in the memory that was selected first, or "Hz" if it is missing in the
memory that was selected second. This may happen parameter data may be missing
when the software versions of two inverters are different.
f_ _ _
N.B.: Parameter titles are written to the inverter memory in consecutive order. When
a_ _ _
F_ _ _
A_ _ _
c_ _ _
C_ _ _
Remote Keypad may stop at the following parameters during the parameter copying, but
(title
this is no problem because these parameters are not needed to copy into the inverter.
number)
Please press the [ENT] key to continue the comparison.
In this case, CRC code will alternately flash when the comparison is completed.
This situation can be prevented by making the same condition (the state of input or output
terminals, and communication options) of the inverter while copying to the inverter.
However, the unique parameters like IP address cannot be set to same value.
c130,c151,c152,c159,c202,c502,c503,c517~c522,c524,
c525~c536,c555,c556,c800
_ _ _ _
When CRC code difference of parameters was found as a result of comparison, two
(4 digits
alternating CRC code indicates appear in the display window. In this case, there is a
_ _ _ _
CRC
different parameter. If the title of different parameter is not found, execute comparison
code)
again after setting "sup" in memory protection function to "off".

7.4. Other problems

Phenomenon
Check the connection of the serial communication cable.
Display is
Check the kind of the serial communication cable.
extinguished.
Check that the power of the inverter is turned on.
When Remote Keypad is connected to the following inverters, % lamp and Hz lamp is
% lamp and Hz
not lit. VF-S11, VF-nC1, VF-S9, VF-A7, VF-P7, etc.
lamp are not lit
Key is not
It needs to be repaired.
[EASY] key is effective only for the inverter with [EASY] key.
effective
Some parameters can't be written while the inverter is running. See the instruction
Parameters
manual of the inverter.
can't be written
Copying the parameters between inverters of different series is impossible.
Remote Keypad indicates missing or mismatched data by flashing a parameter title
number on the display, all prior parameter titles will have been written to the inverter
already.