4.3.4. Memory protection function "prot"

The memory protection function protects the selected memory from being overwritten.
When this function is initiated copying data to the memory is prohibited. Reading the memory data is
permitted.
When all the memories are initialized by memory initialization function (clr), the LED indications
are as follows:
"in", "a", "b", "c" = "off", "sup" = "on"
This is also the default setting at the time of shipment.
Operating procedure
Key
LED indication
"copy"
SFT
"prot"
"prot"
ENT
"in"
SFT
"sup"
"in"
ENT
"in"
"off"
SFT
"off"
ENT
"on"
- If the [ESC] key is pressed, Remote Keypad returns to previous status (except when executing).
(*1) The Protecting operation of "sup" is different from that provided for other memories and is shown below.
With the same inverter types
(capacity, voltage class)
Standard
sup
parameters
on
off
"
": Protection disabled (write permitted), "
(*2) In this case, copying operation of parameters from one inverter to another inverter of a different capacity or
a different voltage class.
"comp"
< Selecting a desired function >
Select "prot" (memory protection function) with the [SFT] key.
< Entering the selected function >
"in"
After selecting "prot" with the [SFT] key, press the [ENT] key and
"in" (selecting inverter memory) appears in the display window.
< Selecting a memory to protect its data >
Each time the [SFT] key is pressed, the display changes as follow
" in"
"a"
"b"
"c"
" a"
" b"
"in"
" c"
"sup" special parameter selection
and to "in" again in this order.
< Entering the memory to protect its data >
After selecting "in" (selecting inverter memory, by way of example)
"off"
with the [SFT] key, press the [ENT] key and the display shows the
present memory protection status. (When "on" appears on the
"on"
display, the selected memory is protected. When "off" appears
on the display, the selected memory is not protected.)
< Protecting the selected memory >
Each time the [SFT] key is pressed, the indication in the display
"on"
changes
"on"
"off"
alternately.
< Executing protection of the selected memory >
After selecting "on" (protecting the selected memory, by way of
example) with the [SFT] key, press the [ENT] key. Remote Keypad
"prot"
starts protecting the selected memory (canceling the protection in
case of "off") and the indication in the display window returns to
"prot".
Special
parameters
Key operation and description
selecting inverter memory
selecting memory A
selecting memory B
selecting memory C
protecting the selected memory (write prohibited)
canceling protection of the selected memory (write
permitted)
With different inverter types
(capacity, voltage class)
Standard
sup
parameters
on
(
2)
*
off
": Write protected (write prohibited)
- 13 -
E6581277
(
1)
*
Special
parameters

Advertisement

Table of Contents
loading

Table of Contents